product description
category: Computers
supplier: Tripp Lite
part #:
SMART1000RM1U Suppliers: Tripp Lite VA Rating: 501-1000 VA Watts: 501-1000 Watts Outlets: 6 Battery Run Time: 1 - 30 minutes
6 outlets 1000 VA 640 watts
| Model |
| Brand |
TRIPP LITE |
| Model |
SMART1000RM1U |
| Input |
- Input Voltage Range
|
120V |
- Input Frequency
|
60Hz +/- 3 Hz |
| Output |
| VA Rating |
1000 VA |
| Watts |
640 Watts |
| Output Voltage |
120V |
| Outlets |
6 NEMA 5-15R |
| Battery |
| Battery Run Time |
Full load runtime: 10 minutes (640 watts)
Half load runtime: 25 minutes (320 watts) |
| Battery Recharge Time |
2-4 hours to 90% |
| Specifications |
| Interface Port |
RS-232,
USB |
| Approvals |
UL1778 (USA), cUL (Canada), Class A (emissions), NOM (Mexico) |
| Surge Protection |
| Data Line Protection |
RJ-11 Modem/Fax/DSL protection |
| Surge Energy Rating |
480 joules |
| Physical Spec |
| Rackmountable |
1U |
| Weight |
32 lbs |
| Dimensions |
1.75" x 17.5" x 16.75" |
| Features |
| Features |
- 1000VA / 640 watt output power capacity compatible with North American 120V / 60Hz power
1U rackmount UPS installs in standard 2 or 4 post 19 inch racks with a depth of only 16.75 inches
Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges
Regulation (AVR) corrects inputs from 83-147VAC back to usable 120V levels without consuming battery power
Line interactive Automatic Voltage Regulation (AVR) corrects inputs from AVR circuits boost undervoltages by 14% depending on the severity and reduces overvoltages by 12%
Network interfaces support simultaneous communications via USB, DB9 serial and SNMPWEBCARD slot
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, internal UPS temperature, AC line frequency, timed inverter shutoff, activate self-test and load bank output power control
Built in Emergency Power Off (EPO) interface with cable
Sine wave output in AC and battery modes
Half load runtime of 24 minutes (500VA / 320 watts) / Full load runtime of 10 minutes (1000VA / 640 watts)
Includes 6 NEMA 5-15R output receptacles arranged in 2 switchable single-outlet load banks
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices
3 stage metered LEDs offer current monitoring and battery charge level
Mains power and voltage regulation LEDs offer at-a-glance power status information
Front panel switches support self-test and alarm cancel functions
UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required
UL (USA), cUL (Canada), NOM (Mexico), FCC Class A (Emissions) listed
|
|