The Complete Guide to 3M Full-Facepiece Reusable Respirators

The Complete Guide to 3M Full-Facepiece Reusable Respirators

When respiratory hazards require additional face and eye coverage, a full facepiece reusable respirator may be an important part of a workplace respiratory protection program. But choosing the right model involves more than selecting a facepiece that covers your entire face.

3M offers several full facepiece respirator families, including the 6000 Series, Ultimate FX FF-400 Series, Secure Click FF-800 Series, and 7800S Series. These products differ in their design, filter connections, comfort features, accessories, and approved operating configurations.

There are also variations within each family, including different sizes, DIN connection models, and prepackaged respirator kits.

In this guide, we'll compare the 17 full facepiece respirator models and kits identified in EIO's catalog, explain their differences, review filter and cartridge compatibility, and help you understand the factors that matter when choosing respiratory protection for industrial applications.

Already familiar with half facepiece respirators? Start with our Complete Guide to 3M Reusable Respirators.

Table of Contents

1. What Is a Full Facepiece Reusable Respirator?

A full facepiece reusable respirator is a respiratory protective device that seals around the face and covers the nose, mouth, and eyes.

Unlike a half facepiece respirator, which covers the nose and mouth, a full facepiece design includes a large lens and a face seal that surrounds the eyes.

When used in an approved air purifying configuration, the respirator removes specified contaminants from ambient air using compatible filters, cartridges, or canisters.

Depending on the exact model and approved accessories, some full facepiece respirators may also be used with powered air purifying or supplied air systems.

Why Choose a Full Facepiece Respirator?

  • Provides respiratory protection in approved configurations
  • Covers the eyes as well as the nose and mouth
  • May offer a higher assigned protection factor than a half facepiece respirator when applicable requirements are met
  • Can accommodate different filters and cartridges, depending on the model
  • Offers reusable construction with replaceable components
  • May be suitable for industrial environments requiring respiratory and eye protection

Important: A full facepiece respirator does not automatically provide protection against every airborne contaminant. Its capabilities depend on the approved configuration, fit, filter or cartridge selection, and workplace conditions.

2. 3M Full Facepiece Respirator Comparison Chart

Although EIO carries multiple model numbers, most belong to a smaller group of major respirator designs.

Respirator Family Notable Features Connection Main Consideration
6000 Series Silicone faceseal, large lens, four-point harness, Cool Flow valve 3M bayonet Straightforward, versatile traditional design
6000DIN Series 6000 family design with additional approved connection options Bayonet and DIN configurations Applications requiring specified DIN configurations
Ultimate FX FF-400 Silicone faceseal, six strap harness, speaking diaphragm, Cool Flow valve 3M bayonet Comfort oriented features and communication
Secure Click FF-800 Push button seal check, speaking diaphragm, six strap harness 3M Secure Click Different cartridge platform and convenient connection features
7800S Series Durable silicone design, double flange seal, six strap harness, optional accessories Bayonet and DIN configurations Industrial versatility and multiple approved operating configurations

The 68097 and 69097 products are mold remediation kits built around 6000 Series facepieces rather than entirely different respirator designs.

3. 3M 6000 Series: 6700, 6800 and 6900

The 3M 6000 Series is a practical starting point for buyers comparing full facepiece reusable respirators.

These respirators feature a soft silicone faceseal, large polycarbonate lens, four-point suspension system, and 3M Cool Flow exhalation valve.

They use the traditional 3M bayonet style filter and cartridge connection, making them compatible with a wide selection of approved 3M particulate filters and gas/vapor cartridges.

Key Features

  • Silicone faceseal
  • Wide field of vision through a large lens
  • Four-point head harness
  • 3M Cool Flow exhalation valve
  • Replaceable components
  • Traditional bayonet filter and cartridge compatibility

Available Models at EIO

Who Should Consider the 6000 Series?

The 6000 Series deserves consideration when you want a traditional full facepiece design with broad access to approved filters, cartridges, and replacement parts.

It can be a starting point for industrial maintenance, construction, manufacturing, and other applications where the specific respirator configuration is appropriate for the exposure.

Our assessment: The 6000 Series provides a useful baseline for comparing more specialized full facepiece families.

4. 3M 6000DIN Series: What's the Difference?

The 6000DIN versions build on the 6000 Series design while providing additional DIN connection capability.

DIN connections are used in certain approved respirator configurations involving compatible canisters or other respiratory protection components.

The major purchasing distinction is compatibility with the specific equipment and approval required for the intended application.

Available DIN Models at EIO

Should You Buy the Standard 6800 or 6800DIN?

Choose between these models based on the required approved respiratory protection system, not simply because one has more connection options.

If you plan to use traditional 3M bayonet filters and cartridges, the standard 6000 Series may meet your needs.

If a particular approved system requires DIN functionality, one of the DIN variants may be appropriate.

Important: A DIN connector does not make every threaded canister or accessory interchangeable. Only use components specifically approved for the respirator and intended operating mode.

5. 3M Ultimate FX FF-400 Series: Comfort and Communication Features

The 3M Ultimate FX FF-400 Series adds several features intended to improve the experience of wearing a full facepiece respirator.

These include a soft silicone faceseal, large lens, six strap harness, 3M Cool Flow exhalation valve, and passive speaking diaphragm.

The speaking diaphragm is designed to improve communication while the respirator is being worn.

Why Consider the Ultimate FX?

  • Silicone faceseal and nose cup
  • Six strap head harness and comfort cradle
  • Passive speaking diaphragm
  • Large lens offering a broad field of view
  • Cool Flow exhalation valve
  • Traditional 3M bayonet compatibility
  • Replaceable lens and other components

Important Update: Lens Coating

Older descriptions of the Ultimate FX may refer to a Scotchgard treated lens.

However, 3M announced a transition away from the Scotchgard coating to an alternative scratch resistant lens coating beginning in late 2024.

Buyers should not assume that newly supplied respirators or replacement lenses include the former Scotchgard coating.

For paint overspray and similar lens contamination concerns, compatible protective lens covers may be worth considering.

Available Ultimate FX Models at EIO

Our assessment: The Ultimate FX FF-400 Series is worth considering for workers who value communication features, a six-strap harness, and the family's comfort-oriented design.

6. 3M Secure Click FF-800 Series: A Different Filter and Cartridge System

The 3M Secure Click FF-800 Series represents a different approach to reusable full facepiece respiratory protection.

Instead of using the traditional bayonet style cartridge connection, the FF-800 uses the 3M Secure Click connection system.

Compatible filters and cartridges are designed to click into place, helping users confirm that the components have engaged.

The FF-800 also includes a push button mechanism for conducting a user seal check, a speaking diaphragm, a silicone faceseal, and a six-strap head harness.

Key Features

  • 3M Secure Click filter and cartridge connection
  • Push button user seal check mechanism
  • Speaking diaphragm
  • Silicone faceseal
  • Six-strap harness and comfort cradle
  • Large protective lens
  • Compatibility with approved Secure Click particulate and gas/vapor products

What Makes Secure Click Different?

Traditional bayonet filters are generally attached with a twisting motion.

Secure Click components use a different push to connect arrangement.

Some Secure Click gas/vapor cartridges also use dual flow designs intended to improve airflow characteristics.

Are Secure Click Cartridges Interchangeable with 6000 Series Cartridges?

No. This is one of the most important purchasing distinctions in the entire 3M full facepiece lineup.

Traditional 3M bayonet cartridges, such as the 6001, 6003, 6006, 60921, and 60923, are not designed to connect directly to the FF-800.

Only approved 3M Secure Click filters and cartridges should be used with this family.

Available Secure Click Models at EIO

Our assessment: The Secure Click FF-800 Series deserves consideration when the connection system, seal check convenience, and communication features are priorities.

However, if your workplace already uses traditional bayonet cartridges, switching to the FF-800 means accounting for a different inventory of compatible filters and cartridges.

7. 3M 7800S Series: Industrial Versatility in Small, Medium and Large

The 3M 7800S Series is designed for industrial environments where durable construction and compatibility with multiple approved respiratory protection configurations may be important.

Unlike some respirator families that are primarily designed for a single operating mode, the 7800S platform can be used in several approved configurations with the appropriate components.

These include selected negative pressure air purifying, powered air purifying, and supplied air applications.

The family features a durable silicone facepiece, double flange faceseal, large lens, and adjustable six-strap harness.

With the addition of medium and large models to the EIO catalog, all three 7800S sizes can now be compared and purchased through the site.

Key Features of the 7800S Series

  • Durable silicone construction
  • Double flange faceseal
  • Six-strap head harness
  • Large lens and wide field of vision
  • Traditional bayonet and specified DIN connection capability
  • Compatibility with selected approved particulate filters and gas/vapor cartridges
  • Optional accessories for selected industrial applications
  • Approved configurations for certain powered air and supplied air systems
  • Replaceable components for maintenance and service
  • Available in small, medium, and large sizes

Shop All Three 7800S Sizes at EIO

Model Size Facepiece Material EIO Product
7800S-S Small Silicone Shop 7800S-S
7800S-M Medium Silicone Shop 7800S-M
7800S-L Large Silicone Shop 7800S-L

What Makes the 7800S Different from the 6000 Series?

Both families use silicone faceseals and support traditional 3M filter systems in approved configurations.

The 7800S adds a double flange faceseal, six-strap harness, and different construction and accessory features.

Its design may appeal to industrial users evaluating multiple respirator operating modes or specialized accessories.

However, the 7800S is not automatically more protective than a properly selected and fitted 6000 Series respirator when both are used in comparable approved negative pressure configurations.

Can the 7800S Be Used for Welding?

3M offers an optional Clip-on Welding Shield Kit 7990 for selected 7800S applications.

This can make the family worth considering for certain welding and metalworking tasks where the complete respiratory and welding protection configuration is suitable.

Always verify compatibility with the required welding protection and the hazards present.

Can the 7800S Be Used with Supplied Air Systems?

Yes. 3M identifies approved powered air and dual airline supplied air configurations for the 7800S family.

However, the facepiece alone does not constitute a complete supplied air respirator.

The correct approved regulator, breathing tube, air supply, fittings, and other system components must be selected.

Similarly, powered air purifying operation requires the appropriate approved blower and filter system.

These are different technologies and must not be treated as interchangeable.

Important Filter Connection Note

Although the 7800S supports both bayonet and DIN connection configurations, the required adapters and components depend on the specific approved setup.

Follow the current 3M user instructions and NIOSH approval label rather than assuming every bayonet cartridge, DIN canister, or accessory connects directly in every configuration.

Our assessment: The 7800S Series is a strong option to evaluate for industrial respiratory protection programs that value durable construction and flexibility across approved system configurations.

8. 3M 68097 and 69097 Mold Remediation Respirator Kits

In addition to individual facepieces, EIO carries two 3M mold remediation respirator kits.

These kits use 6000 Series full facepiece respirators and include P100 particulate filters.

What's Included?

According to 3M, the kits include a full facepiece respirator and two pairs of 3M 2097 P100 particulate filters.

The 2097 provides P100 particulate filtration and nuisance level organic vapor relief.

However, nuisance level organic vapor relief is not equivalent to approved organic vapor cartridge protection for hazardous vapor concentrations.

Available Kits at EIO

These kits may provide a convenient starting configuration for certain assessed particulate exposures during mold remediation.

They should not be assumed suitable for every mold related task or for all cleaning and disinfecting chemicals.

Specific respiratory protection requirements depend on the work, contaminants, exposure assessment, and applicable regulations.

9. Complete 3M Full-Facepiece Model and Size Chart

Use this chart to identify the sizes and variants from the EIO product list covered in this guide.

Family Small Medium Large
6000 Standard 6700 6800 6900
6000DIN 6700DIN 6800DIN 6900DIN
Ultimate FX FF-400 FF-401 FF-402 FF-403
Secure Click FF-800 FF-801 FF-802 FF-803
7800S Series 7800S-S 7800S-M 7800S-L
Mold Remediation Kits Not listed 68097 69097

Important: The same nominal size does not guarantee an identical fit across different facepiece families. Occupational users must be fit tested for the specific respirator make, model, style, and size they will wear.

Some EIO listings also reference case quantities. Review each product's current packaging and ordering information before purchasing.

10. Which Filters and Cartridges Fit 3M Full-Facepiece Respirators?

Filter compatibility is one of the most important differences between these product families.

Traditional Bayonet Models

The standard 6000 Series and Ultimate FX FF-400 Series use traditional 3M bayonet style filters and cartridges in approved configurations.

The 6000DIN and 7800S families also support traditional bayonet filtration in specified approved configurations, although the required adapters and connection components must be verified.

Examples of relevant EIO products include:

Model Protection Category EIO Product
2091 P100 particulate Shop 2091
2097 P100 particulate with nuisance organic vapor relief Shop 2097
7093 Hard-case P100 particulate Shop 7093
6001 Certain organic vapors Shop 6001
6003 Certain organic vapors and acid gases Shop 6003
6006 Certain multiple gases and vapors Shop 6006
60921 Organic vapor/P100 combination Shop 60921
60923 Organic vapor/acid gas/P100 combination Shop 60923
60926 Multi-gas/vapor/P100 combination Shop 60926

These filters and cartridges are not universally suitable for every contaminant. Always verify their NIOSH approvals, use limitations, required adapters, and compatibility with the particular facepiece.

What About DIN Connections?

The 6000DIN and 7800S families provide additional approved connection options, but compatible canisters and accessories must be selected according to the specific NIOSH approvals and 3M instructions.

Do not assume that all DIN threaded products are interchangeable.

What About Secure Click FF-800?

Secure Click FF-800 respirators require approved 3M Secure Click filters and cartridges.

Traditional bayonet products such as the 2091, 6001, or 60921 do not connect directly to an FF-800.

This matters when ordering replacement cartridges or standardizing respiratory protection equipment across a workplace.

Learn More About Filter Selection

11. Common Applications for Full Facepiece Respirators

Full facepiece respirators are used across a variety of industries, but the correct model and configuration depend on the identified exposure.

Industrial Maintenance

Maintenance work may involve dust, vapors, gases, and materials that can also present eye hazards.

Depending on the exposure assessment, a full facepiece respirator may provide an appropriate combined respiratory and eye covering solution.

Painting and Coating

Full facepiece respirators may be considered for certain coating applications when the approved configuration is suitable for the airborne contaminants.

However, spray painting can involve complex exposures, including solvent vapors, paint mist, and potentially isocyanate containing coatings.

Certain spray applications may require supplied air respiratory protection or other specialized controls. An ordinary organic vapor cartridge is not a universal solution for painting.

Construction and Concrete Work

Construction activities may involve silica dust, concrete particles, demolition debris, or other contaminants.

The appropriate filter, assigned protection factor, and respirator type must be selected based on exposure conditions and applicable OSHA requirements.

Read our Best Respirator for Silica Dust Guide.

Welding and Metalworking

Welding and grinding can generate airborne particles, metal fumes, and gases.

The 7800S family offers certain welding-related accessories, but respirator compatibility with welding shields and other required PPE must be verified.

Read our Best Respirator for Welding Guide.

Mold Remediation

Some mold remediation activities can involve significant airborne particulate exposure.

The 68097 and 69097 kits combine full facepiece respirators with P100 filters, but the complete hazard assessment must also account for cleaning agents, disinfectants, and other potential exposures.

12. Half Face vs. Full Face Respirators: What's the Difference?

Both types can provide effective respiratory protection when correctly selected, fitted, and used.

The main distinctions involve coverage, fit, and the assigned protection factor of the complete approved configuration.

Feature Half-Facepiece Full-Facepiece
Face Coverage Nose and mouth Nose, mouth, and eyes
Integrated Eye Coverage No Yes
OSHA APF, Negative Pressure APR 10 50 when applicable requirements are met, including quantitative fit testing
Fit Testing Required for occupational tight-fitting use Required for occupational tight-fitting use
Size and Weight Generally smaller Generally larger

Under OSHA's respiratory protection standard, a negative pressure full facepiece air purifying respirator can have an assigned protection factor of 50 when applicable requirements are met, including appropriate quantitative fit testing.

Qualitative fit testing does not establish the higher protection level required for all applications.

The protection factor can also differ when respirators are used as PAPRs or supplied air systems.

13. Full Face Respirator Fit Testing and OSHA Requirements

Full facepiece respirators rely on an effective seal between the facepiece and the wearer's face.

For required workplace use, OSHA generally requires a respiratory protection program that includes:

  • Medical evaluation before required respirator use
  • Fit testing before initial use
  • Fit testing at least annually
  • Additional testing when a different make, model, style, or size is used
  • Training in respirator use and limitations
  • Appropriate inspection, cleaning, storage, and maintenance
  • Proper filter and cartridge selection
  • Procedures for user seal checks

Qualitative vs. Quantitative Fit Testing

Qualitative fit testing uses a pass/fail response to a test agent.

Quantitative fit testing measures facepiece leakage and produces a numerical fit factor.

For OSHA accepted quantitative fit testing, a tight-fitting full facepiece must generally achieve a fit factor of at least 500 to pass.

Qualitative testing is limited to negative pressure air purifying respirators that need a fit factor of 100 or less.

This distinction is critical when a full facepiece respirator is being selected for a workplace application requiring its higher assigned protection factor.

Important: A user seal check performed each time the respirator is donned does not replace formal fit testing.

Read our OSHA Respiratory Protection Requirements Guide for additional information.

14. Cleaning, Maintenance and Replacement Parts

Reusable respirators must be inspected, maintained, and cleaned according to the manufacturer's instructions and workplace respiratory protection program.

Routine maintenance may include:

  • Inspecting the lens for cracks, damage, or reduced visibility
  • Checking the silicone faceseal for wear or distortion
  • Inspecting inhalation and exhalation valves
  • Checking head straps and buckles
  • Inspecting filter and cartridge connection points
  • Replacing damaged or worn components
  • Cleaning and disinfecting the facepiece using approved procedures
  • Storing the respirator away from contamination and damage

Replacement Lenses and Lens Covers

Different respirator families use different replacement lenses and accessories.

For example, the Ultimate FX FF-400 and Secure Click FF-800 families have distinct replacement lens components.

3M also offers compatible lens covers for selected models to help protect lenses against overspray, debris, and scratching.

Replacement parts should always match the exact facepiece family.

Replacement Cartridges and Filters

Gas/vapor cartridges require an appropriate service life change schedule or certified end of service life indicator where applicable.

Particulate filters have separate replacement considerations, including contamination, damage, increased breathing resistance, and manufacturer restrictions.

Do not wash disposable filter media in an attempt to restore its protective performance.

15. Frequently Asked Questions

What is the difference between the 3M 6800 and FF-402?

Both are medium full facepiece respirators that use traditional 3M bayonet filters and cartridges. The FF-402 adds comfort-oriented features such as a six-strap harness and passive speaking diaphragm, while the 6800 uses a simpler four-point harness design.

What is the difference between the 3M FF-402 and FF-802?

The FF-402 belongs to the Ultimate FX family and uses traditional bayonet connections. The FF-802 belongs to the Secure Click family and requires compatible Secure Click filters and cartridges. Both offer speaking diaphragms and six-strap harness designs.

What is the difference between 6800 and 6800DIN?

The standard 6800 uses the traditional 3M bayonet connection. The 6800DIN adds specified DIN connection capability for approved configurations.

What is the difference between 7800S-S, 7800S-M, and 7800S-L?

They are the small, medium, and large sizes of the same 3M 7800S full facepiece respirator family. Their core design and approved product family features are similar, but each size must be evaluated for proper wearer fit.

Is the 7800S better than the 6800?

The 7800S offers a different silicone design, double flange seal, six strap harness, and additional approved system configurations. However, these differences do not automatically make it more protective than a properly selected and fitted 6800 in a comparable approved operating mode.

Does EIO carry the 7800S in all three sizes?

EIO has product listings for the 7800S-S small, 7800S-M medium, and 7800S-L large. Check each listing for current availability and ordering details.

Are 3M full facepiece respirators made of silicone?

The major families discussed here use silicone faceseals, although other components vary in material and construction.

Which 3M full face respirator is best for long periods of use?

The Ultimate FX FF-400 and Secure Click FF-800 families offer several comfort-oriented features worth considering. However, actual comfort depends on the individual wearer, fit, workload, and other PPE.

Does the 3M FF-800 use 6001 cartridges?

No. The FF-800 uses the Secure Click connection system. The 6001 is a traditional bayonet cartridge.

Can I use 3M 2091 P100 filters with the 6800?

Yes, the 2091 is compatible with the 6800 in approved configurations.

Can I use 3M 60923 cartridges with the FF-402?

Yes, the 60923 organic vapor/acid gas/P100 cartridge is compatible with the Ultimate FX FF-400 family in approved configurations. Suitability for an exposure must be evaluated separately.

Can the 7800S use traditional 3M cartridges?

Yes, in approved configurations with the appropriate required connection components. Always consult the 3M 7800S user instructions and NIOSH approval documentation.

Do full facepiece respirators provide eye protection?

They cover the eyes, and certain models meet specified eye and face protection standards. However, always verify the model's certification and the eye or face hazards present before treating it as a replacement for other required PPE.

Do full face respirators require fit testing?

Yes, when tight-fitting respirators are required for workplace use. The wearer must be tested with the appropriate make, model, style, and size, with testing repeated as required by OSHA.

Can I wear facial hair with a full face respirator?

Facial hair that comes between the sealing surface and the skin or interferes with valve function is prohibited for tight-fitting respirator use under OSHA's respiratory protection standard.

Can a 7800S be used with supplied air?

Yes, the 7800S family has certain approved supplied air configurations. However, the facepiece alone does not supply breathing air and must be combined with the correct approved system components.

Can I use these respirators in oxygen deficient environments?

Not in ordinary air purifying mode. Air purifying respirators do not supply oxygen. Oxygen deficient, IDLH, or unknown atmospheres require specialized respiratory protection selected under applicable regulations.

Are the 68097 and 69097 different respirator designs?

No. They are mold remediation kits using 6000 Series full facepiece respirators, with P100 particulate filters included.

16. Which 3M Full Facepiece Respirator Should You Buy?

There is no single best respirator for every person or workplace.

The right choice depends on the hazard assessment, facepiece fit, required protection factor, approved filters or cartridges, and any other protective equipment being worn.

Choose the 3M 6000 Series If:

  • You prefer a straightforward full facepiece design
  • You want traditional bayonet cartridge compatibility
  • You value access to established replacement parts and accessories

Choose the 3M 6000DIN Series If:

  • Your approved respiratory protection configuration requires specified DIN functionality
  • You have verified the correct compatible canisters and system components

Choose the 3M Ultimate FX FF-400 If:

  • You value a six-strap harness and comfort-oriented features
  • You want a speaking diaphragm
  • You prefer traditional bayonet cartridge compatibility

Choose the 3M Secure Click FF-800 If:

  • You want the Secure Click filter and cartridge connection
  • You value the push button user seal check feature
  • You are prepared to use the corresponding Secure Click filter platform

Choose the 3M 7800S If:

  • You need a durable industrial facepiece platform
  • You value its silicone construction and double flange seal
  • You want to evaluate its optional welding accessories
  • You need to investigate its approved powered air or supplied air configurations
  • You want a family available through EIO in small, medium, and large sizes

Consider the 68097 or 69097 Kits If:

  • You need a 6000 Series facepiece packaged with P100 filters
  • The included filter configuration matches the assessed respiratory hazards
  • You have confirmed the proper facepiece size and fit testing requirements

17. Shop 3M Full Facepiece Reusable Respirators at EIO

Explore the major 3M full facepiece families available through EIO:

3M 6000 Series

3M 6000DIN Series

3M Ultimate FX FF-400 Series

3M Secure Click FF-800 Series

3M 7800S Silicone Full-Facepiece Respirators

3M Mold Remediation Respirator Kits

You can also browse the EIO Reusable Respirators Collection.

Continue Learning About Respiratory Protection

Respirator Safety Disclaimer

This guide is intended for educational and product-comparison purposes. It does not replace a workplace hazard assessment, exposure monitoring, Safety Data Sheets, current 3M user instructions, NIOSH approval documentation, or the advice of a qualified respiratory protection professional.

Respiratory protection must be selected according to the specific contaminants, airborne concentrations, required protection factors, facepiece fit, approved system configuration, work conditions, and applicable regulations.

Air-purifying respirators do not supply oxygen and must not be used in oxygen-deficient, immediately dangerous to life or health (IDLH), or unknown atmospheres.

For required workplace respirator use, employers must follow applicable OSHA respiratory protection requirements, including medical evaluation, fit testing, training, maintenance, filter/cartridge selection, and a written respiratory protection program.

Always verify the approved configuration before purchasing or using a respirator, filter, cartridge, canister, or supplied-air accessory.

Previous post
Back to Knowledge Center

Leave a comment

Please note, comments must be approved before they are published